Production program of our plant provides for manufacturing of copper tubes with inner diameter Ø 5 - 76 mm and wall thickness 0.35-2.5 mm, in soft, half-hard and hard conditions.
FBC Majdanpek manufactures PVC coated copper tubes and copper tubes for use in medicine.
Copper tubes to be used in medicine meet the very strict requirements for production of installations for medical and compressed gasses. They are very safe for conveyance of various gasses in laboratories and hospitals.

Weight and maximum allowable working pressure of fluids are computed using the following equations for each copper tube size:
For weight: |
For pressure:
|
Q = (D - S) x S x π x γ, gr/m |
P = 200 Rm S / DN, bara |
where:
|
where:
|
D - outer diameter, mm
|
200 - conversion constant
|
S - wall thickness, mm
|
Rm - tensile strength, N/mm²
|
γ - specific weight of copper, 8.94 kg/dm³
|
S - wall thickness, mm
|
π - 3,14 |
D - outer diameter, mm
|
| |
N - safety factor (5)
|
We manufacture sanitary and industrial copper tubes mostly of the following standards: EN 1057, EN 12735-1, EN 12449, ASTM B280, ASTM B68/251, ASTM B88, GOST 617, GOST 11383, JUS C.D5-500, JUS C.D5-502 ...

Copper tubes - dimensions, allowable pressures and weights
DxS (mm) |
6x1 |
8x1 |
10x1 |
12x1 |
15x1 |
16x1 |
18x1 |
22x1 |
28x1,5 |
35x1,5 |
42x1,5 |
54x2 |
76x2,5 |
Pressure
(bar)* |
145 |
109 |
87 |
71 |
57 |
52 |
48 |
38 |
46 |
36 |
30 |
31 |
25 |
Weight
(kg/m) |
0,140 |
0,197 |
0,253 |
0,309 |
0,393 |
0,421 |
0,477 |
0,590 |
1,116 |
1,411 |
1,705 |
2,919 |
5,158 |
* Values indicated for pressure in the table above are computed for soft tubes with safety factor N=5. Values indicated for allowable pressure relate only to tubes, not to their joints.
Soft copper tubes
Mechanical properties according to EN 1057 for soft copper tubes
Temper
|
Temper designation
|
Tensile strength (N/mm²)
|
Elongation (%) A5
|
Hardness HV5 (approximately)
|
soft
|
R220
|
min. 220
|
40 |
40 - 70
|
Delivery conditions and packaging for soft copper tubes
Temper designation |
Outer Diameter (mm) |
Wall thickness (mm) |
Delivery condition |
Packaging |
R220 |
5 – 22 |
0,5 – 2,0 |
25 and 50m coils |
Cardboard boxes on palettes
|
R220 |
6 – 20 |
0,5 – 1,0 |
LW coil, 80-120 kg weight |
Cardboard boxes on palettes |
R220 |
5 – 76 |
0,5 – 2,5 |
up to 6 m, straight length |
Cardboard boxes on palettes |



Half-hard copper tubes

Mechanical properties according to EN 1057 for half-hard copper tubes
Temper |
Temper designation |
Tensile strength (N/mm²) |
Elongation (%) A5 |
Hardness HV5 (approximately) |
half-hard
|
R250
|
min. 250
|
30 |
75-100
|
Delivery conditions and packaging for half-hard copper tubes
Temper designation |
Outer Diameter (mm) |
Wall thickness (mm) |
Delivery condition |
Packaging |
R250
|
5 - 76 |
0,5 – 2,5 |
up to 6 m, straight length |
In bundles wrapped in plastic foil |

Hard copper tubes

Mechanical properties according to EN 1057 for hard copper tubes
Temper |
Temper designation |
Tensile strength (N/mm²) |
Elongation (%) A5 |
Hardness HV5 (approximately) |
hard
|
R290
|
min. 290
|
3 |
min.100
|
Delivery conditions and packaging for half-hard copper tubes
Temper designation |
Outer Diameter(mm) |
Wall thickness (mm) |
Delivery condition |
Packaging |
R290
|
5 - 76 |
0,5 – 2,5 |
up to 6 m, straight length
|
In bundles wrapped in plastic foil |

PVC-coated copper tubes

Copper tubes coated with polyvinylchloride (PVC) are intended for water, heating, gas, air, fluid and other installations.
Material used to coat copper tubes is polyvinylchloride (PVC) of the following characteristics:
- Density: 1400 - 1500 kg/m³
- Elongation: 207%
- Breaking strength: 14 N/mm 2
- Maximum working temperature: +95°C
- Minimum bending temperature: -10°C
Advantages of PVC-coated copper tubes are: major reduction of heat loss, prevention of burns in users, PVC coating protects copper tubes from aggressive environments and prolongs its service life. Plastic insulation layer is elastic and enables bending and all other working operations during installation.
FBC Majdanpek can, on buyer’s request, coat with plastic hard and half-hard copper tubes in straight lengths. Soft PVC-coated copper tubes are delivered in coils, while other PVC-coated copper tubes are delivered in straight lengths. The following data can be marked lengthwise on plastic-coated copper tubes:
Manufacturer’s designation
- PVC
- Outer diameter
- Wall thickness
- Quarter/year of production
Plastic coated copper tubes - sizes, weight and allowable pressures:
DxS (mm)
|
6x0,8
|
8x0,8
|
10x0,8
|
12x0,8
|
15x0,8
|
16x0,8
|
18x0,8
|
22x1,0
|
Weight (kg/m)*
|
0,117
|
0,162
|
0,207
|
0,252
|
0,319
|
0,341
|
0,386
|
0,590
|
Flow (l/m)
|
0,015
|
0,032
|
0,055
|
0,085
|
0,141
|
0,163
|
0,211
|
0,314
|
Pressure (bara)*
|
115
|
87
|
69
|
58
|
46
|
44
|
39
|
38
|
* Copper tube weight only (excluding PVC coat)
** For soft copper tubes and safety factor N=5
Standard delivery conditions for plastic-coated copper tubes
Oznaka stanja
|
Prečnik cevi (mm)* |
Oblik isporuke*
|
Način pakovanja
|
R220 (soft)
|
18 -22 |
25 m coil
|
palette
|
R220 (soft)
|
6 -16 |
50m coil
|
palette
|
* Values indicated in the table relate to outer diameter (excluding PVC coat). PVC coat thickness ranges from 1.4 to 2.0 mm.

|
|